Cable protection pipe systems

Installation cables in pipes allows for the use of less expensive cable products and facilitates easier replacement of cable lines during operation, reducing labor costs.

General Product
Catalog

Extended service life - at least 50 years

No corrosion

Easy installation: flexibility and light weight

Wide range of accessories and equipment

Application

Power supply and telecom: simplifies laying underground and protects cables from mechanical damage

Transport infrastructure and monolithic concreting: laying underground along and under roads, railways and airports runways

ELECTROCOR SERIES pipes

Single or double-layer flexible or rigid plastic pipes with corrugated layer.

Application: piping systems protect electrical, telecom and signal cables against mechanical impact and aggressive environment.

Joining method: using fittings

Method of installation: trench method  i ELECTROCOR LIGHT FR recommended for above-ground application (bridges, overpasses)

General properties

 
ELECTROCOR LIGHT,
ELECTROCOR LIGHT PRO
ELECTROCOR LIGHT FR
ELECTROCOR FLEX
ELECTROCOR
ELECTROCOR PRO
Diameters
DN/OD, mm
50-160 50-160 50-200 50-250 90-250
Compression resistance 250 N,
1250 N
450 N,
750 N
450 N 750 N 1250 N
Impact resistance L (light),
N (normal)
L (light),
N (normal)
L (light) N (normal) S (strong)
Bending strength flexible flexible flexible rigid rigid
Bending radius, not less than 3d
Tightness of connections, GOST 14254-96: up to IP66 IP66
Insulation resistance, MOm, more than 100
Electrical strength, min., not less than 15
Thermal stability at a temperature of 200°C, min., not less than 20


ELECTROCOR fittings

Diameters, mm; DN/OD
50
63
75
90
110
160
200
250
End cap
Clip coupler
Coupler
Sealing ring
Spacer
 

 

 

 

i DN/OD 110 – double,
DN/OD 110 – triple

i DN/OD 160 – double

i DN/OD 200 – single

 




ELECTROPIPE series and ELECTROPIPE RS series pipes with increased heat stability

Made from halogen-free plastic pipes do not emit harmful substances under the influence of flame. Solid wall has improved operating characteristics for protecting insulated electrical wires and /or cables from corrosive environment and mechanical impact at maximum transport load.

Connection method: butt fusion using heated tool or using electrofusion fitting.

Installation method: trench or trenchless including horizontal directional drilling.



ELECTROPIPE SERIES pipes

 
ELECTROPIPE
ELECTROPIPE PRO
Diameters
DN/OD, mm
50-280
Compression resistance 450 N, 750 N, 1250 N
Impact resistance N (normal)
Bending strength rigid
Bending radius, not less than 20d
Tightness of connections, GOST 14254-96: up to IP66 IP68




ELECTROPIPE RS series pipes

 
ELECTROPIPE RS
ELECTROPIPE PRO RS
ELECTROPIPE FR RS
ELECTROPIPE FR RS LD
ELECTROPIPE NF RS
Diameters
DN/OD, mm
50–630 90-225 50-630
Compression resistance SN4, SN8, SN12, SN14, SN16, SN24, SN32, SN48, SN56, SN64, SN96, SN192
Impact resistance N (normal), S (strong)
Bending radius, not less than 20d




Fittings for ELECTROPIPE, ELECTROPIPE RS series pipes

Diameters, mm; DN/OD
50
63
75
90
110
160
200
250
280
End cap
Injection molded end cap
Electropipe coupler
Coupler
Seamless bends
 

 

 

 
Funnels
 




PE protective pipes for communication lines (PPP)

Double layer solid-wall pipes with gliding inner layer.

Application: mechanical protection of fiber optic lines from vibration and mechanical damage during installation underground, crossing water obstacles with and without digging-in, along the bridges and cable trays.

Installation method: trench, trenchless including horizontal directional drilling.

Connection method: electrofusion welding (using fittings).

Diameters, mm
 

20-110

Impact resistance
 

L (light),
N (normal)

Bending radius,
not less than

20d

IP Code
 

IP68

Thermal stability at 200°C, min.,
not less than

20

Friction coefficient,
no more than

0,15





Telepipe series pipes for telecommunication infrastructure

Single microducts or multiple pipe systems

Microducts: OD/ID 16/12 mm.

Types of microducts: TELEPIPE – single layer duct with smooth inner surface; TELEPIPE C – single layer duct with grooved inner surface.

Types of multiple pipe system (bundles): consist of two or more microducts, united by a protective polymer jacket into one or two blocks with a connecting jumper. Bundles design and color markings upon request.





PE cable manholes KKSP-PRO

PE manholes provide reliable mechanical protection of electric and cable lines from precipitation and temperature change. All manholes are tested for integrity.

Application: cable piping (low voltage and power systems) at various transport loads.

Key advantages:

  • reliable protection of electrical and telecom cables from precipitation and temperature changes;
  • integrity proved by laboratory testing;
  • great dielectric properties, thermal stability;
  • resistance to corrosion and possibility to install in aggressive grounds;
  • nominal ring stiffness of manhole shaft SN2, reinforced injection-moulded bottomi.

Manholes design depends on the conditions of cable pipeline installation and determined by the project. Custom made manholes are available upon request. If necessary the shaft of the manhole can be produced with additional inner protective layer. Each manhole come with a drawing.





Standard size of KKSP-PRO

Manhole type Inner diameter, mm Shaft height, mm Overall height, mm
KKSP-PRO -2 1000 1386 1500
KKSP-PRO -3b 1300 1650 1770
KKSP-PRO -4 1600 1800 2014
KKSP-PRO -5 2000 1800 2028




It is possible to manufacture manholes KKSP-Mini for telecommunication infrastructure.

Also it is possible to produce manholes or other structures based on plastic panels POLYPROPANEL.