Cable protection pipe systems
Installation cables in pipes allows for the use of less expensive cable products and facilitates easier replacement of cable lines during operation, reducing labor costs.
Installation cables in pipes allows for the use of less expensive cable products and facilitates easier replacement of cable lines during operation, reducing labor costs.
Extended service life - at least 50 years
No corrosion
Easy installation: flexibility and light weight
Wide range of accessories and equipment
Power supply and telecom: simplifies laying underground and protects cables from mechanical damage
Transport infrastructure and monolithic concreting: laying underground along and under roads, railways and airports runways
Single or double-layer flexible or rigid plastic pipes with corrugated layer.
Application: piping systems protect electrical, telecom and signal cables against mechanical impact and aggressive environment.
Joining method: using fittings
Method of installation: trench method ELECTROCOR LIGHT FR recommended for above-ground application (bridges, overpasses)
ELECTROCOR LIGHT,
ELECTROCOR LIGHT PRO |
ELECTROCOR LIGHT FR
|
ELECTROCOR FLEX
|
ELECTROCOR
|
ELECTROCOR PRO
|
|
|---|---|---|---|---|---|
Diameters DN/OD, mm |
50-160 | 50-160 | 50-200 | 50-250 | 90-250 |
Compression resistance |
250 N, 1250 N |
450 N, 750 N |
450 N | 750 N | 1250 N |
Impact resistance |
L (light), N (normal) |
L (light), N (normal) |
L (light) | N (normal) | S (strong) |
Bending strength |
flexible | flexible | flexible | rigid | rigid |
Bending radius, not less than |
3d | ||||
Tightness of connections, GOST 14254-96: up to IP66 |
IP66 | ||||
Insulation resistance, MOm, more than |
100 | ||||
Electrical strength, min., not less than |
15 | ||||
Thermal stability at a temperature of 200°C, min., not less than |
20 | ||||
| Diameters, mm; DN/OD |
50
|
63
|
75
|
90
|
110
|
160
|
200
|
250
|
|---|---|---|---|---|---|---|---|---|
End cap |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Clip coupler |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Coupler |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Sealing ring |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Spacer |
![]() |
![]() |
![]() |
![]() |
![]() DN/OD 110 – double, DN/OD 110 – triple |
![]() DN/OD 160 – double |
![]() DN/OD 200 – single |
![]() |
Made from halogen-free plastic pipes do not emit harmful substances under the influence of flame. Solid wall has improved operating characteristics for protecting insulated electrical wires and /or cables from corrosive environment and mechanical impact at maximum transport load.
Connection method: butt fusion using heated tool or using electrofusion fitting.
Installation method: trench or trenchless including horizontal directional drilling.
ELECTROPIPE
|
ELECTROPIPE PRO
|
|
|---|---|---|
Diameters DN/OD, mm |
50-280 | |
Compression resistance |
450 N, 750 N, 1250 N | |
Impact resistance |
N (normal) | |
Bending strength |
rigid | |
Bending radius, not less than |
20d | |
Tightness of connections, GOST 14254-96: up to IP66 |
IP68 | |
ELECTROPIPE RS
|
ELECTROPIPE PRO RS
|
ELECTROPIPE FR RS
|
ELECTROPIPE FR RS LD
|
ELECTROPIPE NF RS
|
|
|---|---|---|---|---|---|
Diameters DN/OD, mm |
50–630 | 90-225 | 50-630 | ||
Compression resistance |
SN4, SN8, SN12, SN14, SN16, SN24, SN32, SN48, SN56, SN64, SN96, SN192 | ||||
Impact resistance |
N (normal), S (strong) | ||||
Bending radius, not less than |
20d | ||||
| Diameters, mm; DN/OD |
50
|
63
|
75
|
90
|
110
|
160
|
200
|
250
|
280
|
|---|---|---|---|---|---|---|---|---|---|
End cap |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Injection molded end cap |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Electropipe coupler |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Coupler |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Seamless bends |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Funnels |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Double layer solid-wall pipes with gliding inner layer.
Application: mechanical protection of fiber optic lines from vibration and mechanical damage during installation underground, crossing water obstacles with and without digging-in, along the bridges and cable trays.
Installation method: trench, trenchless including horizontal directional drilling.
Connection method: electrofusion welding (using fittings).
Diameters, mm20-110
Impact resistanceL (light),
N (normal)
Bending radius,20d
IP CodeIP68
Thermal stability at 200°C, min.,20
Friction coefficient,0,15
Microducts: OD/ID 16/12 mm.
Types of microducts: TELEPIPE – single layer duct with smooth inner surface; TELEPIPE C – single layer duct with grooved inner surface.
Types of multiple pipe system (bundles): consist of two or more microducts, united by a protective polymer jacket into one or two blocks with a connecting jumper. Bundles design and color markings upon request.
PE manholes provide reliable mechanical protection of electric and cable lines from precipitation and temperature change. All manholes are tested for integrity.
Application: cable piping (low voltage and power systems) at various transport loads.
Manholes design depends on the conditions of cable pipeline installation and determined by the project. Custom made manholes are available upon request. If necessary the shaft of the manhole can be produced with additional inner protective layer. Each manhole come with a drawing.
| Manhole type | Inner diameter, mm | Shaft height, mm | Overall height, mm |
|---|---|---|---|
| KKSP-PRO -2 | 1000 | 1386 | 1500 |
| KKSP-PRO -3b | 1300 | 1650 | 1770 |
| KKSP-PRO -4 | 1600 | 1800 | 2014 |
| KKSP-PRO -5 | 2000 | 1800 | 2028 |
It is possible to manufacture manholes KKSP-Mini for telecommunication infrastructure.
Also it is possible to produce manholes or other structures based on plastic panels POLYPROPANEL.